TD120-MC
Tangens Delta diagnostics system

Tan Delta measurement is a proven, simple and reliable test method for evaluating the dielectric condition and a degree of degradation of the HV cables. Damages on cables caused by water trees can be easily and clearly identified.
VLF test sets of the HVA series with corresponding voltage range serve as the ideal high voltage source for the TD120-MC device.

Performance: Accurate TD measurement for variable frequencies in the range of VLF (i.e. 0.01 to 0.1 Hz).

Application: Suitable for testing XLPE, PE, EPR and PILC cables or other electrical equipment.

Safe connection: There is no need to connect the device with the PC, a safe Bluetooth connection is available. 

Clear set up: Easy handling, easy wiring, all steps clearly covered in just few steps.

Compliance: TD120-MC device is in compliance with the guide IEEE 400.2 and the standard HD 620 with its local derivations.

Operating voltage (sine wave) max. 120 kVpeak, 85 kVrms
Tan Delta (resolution / accuracy)

1 x 10-5 / ± 1 x 10-4

CHARACTERISTICS

COMPACT AND PORTABLE

Our TD systems have been designed for maximum portability and on-site use. This makes them utilizable for versatile applications, e.g. off-shore.

TRUE MODULARITY

Multi-contact feature (-MC in the name) makes TD120-MC easily extended to any HVA test set, with corresponding voltage range, to a complete diagnostics system. This keeps the initial investment low.

Automatic mode

With the corresponding b2 Suite software, you get manual and incremental test modes with self-explanatory menus, as well as a fully automatic measurement mode reducing operation efforts.

MONITORED WITHSTAND TEST

In combination with the b2 Suite v2 software, this TD device provides an additional comprehensive assessment (acc. IEEE 400.2) of your cable system, live.

your benefits

  • easy handling
  • testing and diagnostics simultaneously; at variable frequencies
  • when carried out at fixed intervals, TD testing can be the basis
    of a predictive maintenance program for your HV cables

  • transfer of test results via Bluetooth
  • graphical display with clear interpretation of the values, offering 
    a fast and accurate assessment of the dielectric condition of the cable

  • no complicated wiring
  • also testing of very short cables > 500 pF
  • fully automatic reporting via tailor-made software tool

We use cookies on our website. Some of them are technically necessary, while others help us to improve this website or provide additional functionality. By using it, you agree to our cookie policy.